# MQTT API
The device is capable to register to a MQTT broker to publish data and subscribe to specific topics.
The MQTT service has to be enabled and configured properly in the device configuration via web interface (`Settings` -> `Configuration` -> section `MQTT`)
The following parameters have to be defined:
* URI
* MainTopic (optional, if not set, the hostname is used)
* ClientID (optional, if not set, `AIOTED-` + the MAC address gets used to make sure the ID is unique)
* User (optional)
* Password (optional)
* RetainFlag (optional)
## Published topics
### Status
`MainTopic`/{status topic}, e.g. `watermeter/status`
* #### Connection
* #### Interval
* #### MAC
* #### IP
* #### Hostname
* #### Uptime
* #### FreeMem
* #### WifiRSSI
* #### CPUTemp
* #### Status
### Result
`MainTopic`/{NumberName}/{result topic}, e.g. `watermeter/main/value`
* #### Value
* #### Raw
* #### Error
* #### JSON
* #### Rate
* #### Rate_per_time_unit
The time Unit gets set with the Homeassistant Discovery, eg. `h` or `m` (minutes)
* #### Rate_per_digitalization_round
The `interval` defines when the next round gets triggered
* #### Changeabsolut
* #### Timestamp
* #### JSON
All relevant results in JSON syntax
### GPIO
`MainTopic`/{GPIO topic}, e.g. `watermeter/GPIO/GPIO12`
* #### GPIO/GPIO{PinNumber}
Depending on device configuration (`Settings` --> `Configuration` --> Chapter `GPIO`)
## Subscibed topics
`MainTopic`/{subscribed topic}, e.g. `watermeter/ctrl/flow_start`
### Control
* #### ctrl/flow_start
Trigger a flow start by publishing to this topic (any character, length > 0)
* #### GPIO/GPIO{PinNumber}
Depending on device configuration (`Settings` --> `Configuration` --> Chapter `GPIO`)