Display ON, OFF and TOGGLE action

Fixes #15
This commit is contained in:
GrKoR
2022-04-08 01:31:43 +03:00
parent 8bead4b920
commit b5845e054e
3 changed files with 89 additions and 11 deletions

View File

@@ -0,0 +1,35 @@
#pragma once
#include "esphome/core/component.h"
#include "esphome/core/automation.h"
#include "aux_ac.h"
namespace esphome {
namespace aux_ac {
template <typename... Ts>
class AirConDisplayOffAction : public Action<Ts...>
{
public:
explicit AirConDisplayOffAction(AirCon *ac) : ac_(ac) {}
void play(Ts... x) override { this->ac_->displaySequence(AC_DISPLAY_OFF); }
protected:
AirCon *ac_;
};
template <typename... Ts>
class AirConDisplayOnAction : public Action<Ts...>
{
public:
explicit AirConDisplayOnAction(AirCon *ac) : ac_(ac) {}
void play(Ts... x) override { this->ac_->displaySequence(AC_DISPLAY_ON); }
protected:
AirCon *ac_;
};
} // namespace aux_ac
} // namespace esphome

View File

@@ -2352,6 +2352,36 @@ class AirCon : public esphome::Component, public esphome::climate::Climate {
return true;
}
// загружает на выполнение последовательность команд на включение/выключение табло с температурой
bool displaySequence(ac_display dsp = AC_DISPLAY_ON){
// нет смысла в последовательности, если нет коннекта с кондиционером
if (!get_has_connection()) {
_debugMsg(F("displaySequence: no pings from HVAC. It seems like no AC connected."), ESPHOME_LOG_LEVEL_ERROR, __LINE__);
return false;
}
if (dsp == AC_DISPLAY_UNTOUCHED) return false; // выходим, чтобы не тратить время
// формируем команду
ac_command_t cmd;
_clearCommand(&cmd); // не забываем очищать, а то будет мусор
cmd.display = dsp;
// добавляем команду в последовательность
if (!commandSequence(&cmd)) return false;
_debugMsg(F("displaySequence: loaded (display = %02X)"), ESPHOME_LOG_LEVEL_VERBOSE, __LINE__, dsp);
return true;
}
// выключает экран
bool displayOffSequence(){
return displaySequence(AC_DISPLAY_OFF);
}
// включает экран
bool displayOnSequence(){
return displaySequence(AC_DISPLAY_ON);
}
void set_period(uint32_t ms) { this->_update_period = ms; };
uint32_t get_period() { return this->_update_period; };
void set_show_action(bool show_action) { this->_show_action = show_action; };
@@ -2401,16 +2431,6 @@ class AirCon : public esphome::Component, public esphome::climate::Climate {
if (get_has_connection()) getStatusBigAndSmall();
}
/*
// это экспериментальная секция для отладки функционала
static uint32_t debug_millis = millis();
if (millis()-debug_millis > 10000){
debug_millis = millis();
//_debugMsg(F("Test!"), ESPHOME_LOG_LEVEL_WARN, __LINE__);
//if (_current_ac_state.power == AC_POWER_OFF) powerSequence(AC_POWER_ON);
//else powerSequence(AC_POWER_OFF);
}
*/
};
};

View File

@@ -2,6 +2,8 @@ import logging
import esphome.config_validation as cv
import esphome.codegen as cg
from esphome.components import climate, uart, sensor
from esphome import automation
from esphome.automation import maybe_simple_id
from esphome.const import (
CONF_ID,
CONF_UART_ID,
@@ -19,6 +21,7 @@ from esphome.components.climate import (
ClimatePreset,
ClimateSwingMode,
)
_LOGGER = logging.getLogger(__name__)
CODEOWNERS = ["@GrKoR"]
@@ -35,6 +38,9 @@ aux_ac_ns = cg.esphome_ns.namespace("aux_ac")
AirCon = aux_ac_ns.class_("AirCon", climate.Climate, cg.Component)
Capabilities = aux_ac_ns.namespace("Constants")
AirConDisplayOffAction = aux_ac_ns.class_("AirConDisplayOffAction", automation.Action)
AirConDisplayOnAction = aux_ac_ns.class_("AirConDisplayOnAction", automation.Action)
ALLOWED_CLIMATE_MODES = {
"HEAT_COOL": ClimateMode.CLIMATE_MODE_HEAT_COOL,
"COOL": ClimateMode.CLIMATE_MODE_COOL,
@@ -130,4 +136,21 @@ async def to_code(config):
cg.add(var.set_custom_presets(config[CONF_CUSTOM_PRESETS]))
if CONF_CUSTOM_FAN_MODES in config:
cg.add(var.set_custom_fan_modes(config[CONF_CUSTOM_FAN_MODES]))
DISPLAY_ACTION_SCHEMA = maybe_simple_id(
{
cv.Required(CONF_ID): cv.use_id(AirCon),
}
)
@automation.register_action("aux_ac.display_off", AirConDisplayOffAction, DISPLAY_ACTION_SCHEMA)
async def switch_toggle_to_code(config, action_id, template_arg, args):
paren = await cg.get_variable(config[CONF_ID])
return cg.new_Pvariable(action_id, template_arg, paren)
@automation.register_action("aux_ac.display_on", AirConDisplayOnAction, DISPLAY_ACTION_SCHEMA)
async def switch_toggle_to_code(config, action_id, template_arg, args):
paren = await cg.get_variable(config[CONF_ID])
return cg.new_Pvariable(action_id, template_arg, paren)