@@ -123,6 +123,10 @@ climate:
|
||||
name: AC Preset Reporter
|
||||
id: ac_preset_reporter
|
||||
internal: false
|
||||
vlouver_state:
|
||||
name: AC Vertical Louvers State
|
||||
id: ac_vlouver_state
|
||||
internal: false
|
||||
visual:
|
||||
min_temperature: 16
|
||||
max_temperature: 32
|
||||
@@ -176,7 +180,8 @@ climate:
|
||||
- **defrost_state** (*Optional*): The information for the HVAC defrost function state sensor (is it ON or OFF). All settings are the same as for the **display_state** (see description above).
|
||||
- **invertor_power** (*Optional*): The information for the invertor power sensor. All settings are the same as for the **display_state** (see description above).
|
||||
- **preset_reporter** (*Optional*): Parameters of text sensor with current preset. All settings are the same as for the **display_state** (see description above).
|
||||
ESPHome Climate devices are not report their active presets (from **supported_presets** and **custom_presets** lists) to MQTT. In case you are using mqtt and want to receive information about active preset you should declare this sensor in your yaml.
|
||||
ESPHome Climate devices are not report their active presets (from **supported_presets** and **custom_presets** lists) to MQTT. In case you are using mqtt and want to receive information about active preset you should declare this sensor in your yaml.
|
||||
- **vlouver_state** (*Optional*): Parameters of vertical louvers state sensor. All settings are the same as for the **display_state** (see description above). The state of the vertical louvers is encoded by the integer value (see [aux_ac.vlouver_set action](#aux_ac_._vlouver_set) below).
|
||||
- **supported_modes** (*Optional*, list): List of supported modes. Possible values are: ``HEAT_COOL``, ``COOL``, ``HEAT``, ``DRY``, ``FAN_ONLY``. Please note: some manufacturers call AUTO mode instead of HEAT_COOL. Defaults to ``FAN_ONLY``.
|
||||
- **custom_fan_modes** (*Optional*, list): List of supported custom fan modes. Possible values are: ``MUTE``, ``TURBO``. No custom fan modes by default.
|
||||
- **supported_presets** (*Optional*, list): List of supported presets. Possible values are: ``SLEEP``. No presets by default.
|
||||
@@ -205,6 +210,28 @@ on_...:
|
||||
```
|
||||
- **aux_id** (**Requared**, string): ID of `aux_ac` component.
|
||||
|
||||
### ``aux_ac.vlouver_set`` ###
|
||||
This action moves HVAC vertical louvers to the specified position.
|
||||
|
||||
The position is encoded by the following values:
|
||||
- `0`: the vertical louvers are in `SWING` mode (they are moving up and down);
|
||||
- `1`: the louvers are stopped in a user position;
|
||||
- `2`: the louvers are in the topmost position;
|
||||
- `3`: the louvers are in one step above middle position;
|
||||
- `4`: the louvers are in the middle position;
|
||||
- `5`: the louvers are in one step below middle position;
|
||||
- `6`: the louvers are in the lowest position.
|
||||
|
||||
```yaml
|
||||
on_...:
|
||||
then:
|
||||
- aux_ac.vlouver_set:
|
||||
id: aux_id
|
||||
position: 3 # moves the louvers to the middle position
|
||||
```
|
||||
- **aux_id** (**Requared**, string): ID of `aux_ac` component.
|
||||
- **position** (**Requared**, integer): position of the vertical louvers.
|
||||
|
||||
### ``aux_ac.vlouver_stop`` ###
|
||||
This action stops vertical swing of louvers.
|
||||
|
||||
|
||||