* still needs to be tested https://github.com/jomjol/AI-on-the-edge-device/issues/3143 * Update ClassFlowPostProcessing.cpp code formatting * Update ClassFlowDefineTypes.h code formatting * Update ClassFlowPostProcessing.h code formatting * Update edit_config_template.html * fix * Update config.ini * Update edit_config_template.html * Updated param doc * Rename parameters * Update edit_config_template.html * Update NUMBER.ChangeRateThreshold.md * Update NUMBER.ChangeRateThreshold.md --------- Co-authored-by: CaCO3 <caco3@ruinelli.ch>
This commit is contained in:
@@ -0,0 +1,25 @@
|
||||
# Parameter `<NUMBER>.ChangeRateThreshold`
|
||||
Default Value: `2`
|
||||
|
||||
Range: `1` .. `9`.
|
||||
|
||||
Threshold parameter for change rate detection.<br>
|
||||
This parameter is intended to compensate for small reading fluctuations that occur when the meter does not change its value for a long time (e.g. at night) or slightly turns backwards. This can eg. happen on watermeters.
|
||||
|
||||
It is only applied to the last digit of the read value (See example below).
|
||||
If the read value is within PreValue +/- Threshold, no further calculation is carried out and the Value/Prevalue remains at the old value.
|
||||
|
||||
Example:
|
||||
|
||||
Smallest ROI provides value for 0.000x
|
||||
ChangeRateThreshold = 2
|
||||
|
||||
Extended Resolution disabled:
|
||||
PreValue: 123.456'7 >>> Threshold = +/- 0.000'2
|
||||
Comparative value >>> max = 123.456'9 and min = 123.456'5
|
||||
|
||||
Extended Resolution enabled:
|
||||
PreValue: 123.456'78 >>> Threshold = +/- 0.000'02
|
||||
Comparative value >>> max = 123.456'80 and min = 123.456'76
|
||||
|
||||

|
||||