Update Homeassistant discovery (#3580)

* use "total" for Homeassistant discovery topic "raw" if AllowNegativeRates is activ (same as for "value")

* update webUI

* .

* .

* .

* formating

* use state class "measurement" in case of a thermometer

* Update edit_config_template.html

---------

Co-authored-by: CaCO3 <caco@ruinelli.ch>
This commit is contained in:
CaCO3
2025-03-01 00:28:38 +01:00
committed by GitHub
parent 00ac2130c2
commit 94a53b38b8
5 changed files with 44 additions and 23 deletions

View File

@@ -195,9 +195,12 @@ bool MQTThomeassistantDiscovery(int qos) {
/* If "Allow neg. rate" is true, use "measurement" instead of "total_increasing" for the State Class, see https://github.com/jomjol/AI-on-the-edge-device/issues/3331 */
std::string value_state_class = "total_increasing";
if ((*NUMBERS)[i]->AllowNegativeRates) {
if (meterType == "temperature") {
value_state_class = "measurement";
}
else if ((*NUMBERS)[i]->AllowNegativeRates) {
value_state_class = "total";
}
/* Energy meters need a different Device Class, see https://github.com/jomjol/AI-on-the-edge-device/issues/3333 */
std::string rate_device_class = "volume_flow_rate";
@@ -205,17 +208,17 @@ bool MQTThomeassistantDiscovery(int qos) {
rate_device_class = "power";
}
// Group | Field | User Friendly Name | Icon | Unit | Device Class | State Class | Entity Category
allSendsSuccessed |= sendHomeAssistantDiscoveryTopic(group, "value", "Value", "gauge", valueUnit, meterType, value_state_class, "", qos); // State Class = "total_increasing" if <NUMBERS>.AllowNegativeRates = false, else use "measurement"
allSendsSuccessed |= sendHomeAssistantDiscoveryTopic(group, "raw", "Raw Value", "raw", valueUnit, meterType, "measurement", "diagnostic", qos);
allSendsSuccessed |= sendHomeAssistantDiscoveryTopic(group, "error", "Error", "alert-circle-outline", "", "", "", "diagnostic", qos);
// Group | Field | User Friendly Name | Icon | Unit | Device Class | State Class | Entity Category | QoS
allSendsSuccessed |= sendHomeAssistantDiscoveryTopic(group, "value", "Value", "gauge", valueUnit, meterType, value_state_class, "", qos); // State Class = "total_increasing" if <NUMBERS>.AllowNegativeRates = false, "measurement" in case of a thermometer, else use "total".
allSendsSuccessed |= sendHomeAssistantDiscoveryTopic(group, "raw", "Raw Value", "raw", valueUnit, meterType, value_state_class, "diagnostic", qos);
allSendsSuccessed |= sendHomeAssistantDiscoveryTopic(group, "error", "Error", "alert-circle-outline", "", "", "", "diagnostic", qos);
/* Not announcing "rate" as it is better to use rate_per_time_unit resp. rate_per_digitization_round */
// allSendsSuccessed |= sendHomeAssistantDiscoveryTopic(group, "rate", "Rate (Unit/Minute)", "swap-vertical", "", "", "", ""); // Legacy, always Unit per Minute
allSendsSuccessed |= sendHomeAssistantDiscoveryTopic(group, "rate_per_time_unit", "Rate (" + rateUnit + ")", "swap-vertical", rateUnit, rate_device_class, "measurement", "", qos);
allSendsSuccessed |= sendHomeAssistantDiscoveryTopic(group, "rate_per_digitization_round", "Change since last Digitization round", "arrow-expand-vertical", valueUnit, "", "measurement", "", qos); // correctly the Unit is Unit/Interval!
allSendsSuccessed |= sendHomeAssistantDiscoveryTopic(group, "timestamp", "Timestamp", "clock-time-eight-outline", "", "timestamp", "", "diagnostic", qos);
allSendsSuccessed |= sendHomeAssistantDiscoveryTopic(group, "json", "JSON", "code-json", "", "", "", "diagnostic", qos);
allSendsSuccessed |= sendHomeAssistantDiscoveryTopic(group, "problem", "Problem", "alert-outline", "", "problem", "", "", qos); // Special binary sensor which is based on error topic
// allSendsSuccessed |= sendHomeAssistantDiscoveryTopic(group, "rate", "Rate (Unit/Minute)", "swap-vertical", "", "", "", "", qos); // Legacy, always Unit per Minute
allSendsSuccessed |= sendHomeAssistantDiscoveryTopic(group, "rate_per_time_unit", "Rate (" + rateUnit + ")", "swap-vertical", rateUnit, rate_device_class, "measurement", "", qos);
allSendsSuccessed |= sendHomeAssistantDiscoveryTopic(group, "rate_per_digitization_round","Change since last Digitization round", "arrow-expand-vertical", valueUnit, "", "measurement", "", qos); // correctly the Unit is Unit/Interval!
allSendsSuccessed |= sendHomeAssistantDiscoveryTopic(group, "timestamp", "Timestamp", "clock-time-eight-outline", "", "timestamp", "", "diagnostic", qos);
allSendsSuccessed |= sendHomeAssistantDiscoveryTopic(group, "json", "JSON", "code-json", "", "", "", "diagnostic", qos);
allSendsSuccessed |= sendHomeAssistantDiscoveryTopic(group, "problem", "Problem", "alert-outline", "", "problem", "", "", qos); // Special binary sensor which is based on error topic
}
LogFile.WriteToFile(ESP_LOG_DEBUG, TAG, "Successfully published all Homeassistant Discovery MQTT topics");