# Migration from water-meter „old“ to water-meter “AI-on-the-edge-device”
!!! Warning
This page no longer is maintained!
There are only some few steps necessary to migrate your old system to the new one.
Please follow the following steps:
#### 1. Follow the installation guide to flash the ESP32CAM and prepare a SD Card with the content of the master
#### 2. Save the following files from the old Docker system on your PC:
* Reference Points 1-3 (only 2 needed)
* `Config.ini`
#### 3. Copy Reference Points 1-3 onto the new water-meter system (Directory `/config`)
**Please note only two Reference Points are supported in the new system.**
#### 4. Open new `config.ini` File:
Insert from the old `Config.ini` file `[alignment]` and `[alignment.ref0]` and `[alignment.ref1]` section the two Ref x and y position and the `initial_rotation_angle= 123`into the new `Config.ini` File, e.g.:
###### Old:
```
[alignment.ref0]
image=./config/RB01_65x65.jpg
pos_x=28
pos_y=63
[alignment.ref1]
image=./config/RB02_50x35.jpg
pos_x=497
pos_y=127
[alignment]
initial_rotation_angle=180
```
###### New:
```
[Alignment]
InitalRotate=180
/config/RB01_65x65.jpg 28, 63
/config/RB02_50x35.jpg 497, 127
SearchFieldX = 20
SearchFieldY = 20
```
#### 5. Insert the old Digit Values into the new `Config.ini` File, e.g.:
###### Old:
```
[Digital_Digit.ziffer1]
pos_x=265
pos_y=117
dx=28
dy=51
[Digital_Digit.ziffer2]
pos_x=310
pos_y=117
dx=28
dy=51
[Digital_Digit.ziffer3]
pos_x=354
pos_y=117
dx=28
dy=51
[Digital_Digit.ziffer4]
pos_x=399
pos_y=117
dx=28
dy=51
[Digital_Digit.ziffer5]
pos_x=445
pos_y=115
dx=28
dy=51
```
###### New:
```
[Digits]
Model=/config/dig0630s3.tflite
;LogImageLocation = /log/digit
ModelInputSize 20, 32
digit1, 265, 117, 28, 51
digit2, 310, 117, 28, 51
digit3, 354, 117, 28, 51
digit4, 399, 117, 28, 51
digit5, 445, 115, 28, 51
```
#### 6. Make sure that you have the same quality and size settings as in your old `Config.ini`
In the old configuration this was coded in the html-string for the image source:
###### Old:
```
URLImageSource=http://IP-ADRESS/capture_with_flashlight?quality=5&size=VGA
```
Default was Quality=5 and VGA.
###### New:
```
ImageQuality = 5
ImageSize = VGA
```
#### 7. Repeat the same for the analog section
#### 8. Insert your SSID and Password into the new wlan.ini File
#### 9. Compare and edit [ConsistencyCheck] Section with new [PostProcessing] Section
#### 10. Save new config.ini File in the new System.
#### 11. Restart the system.
#### 12. After the first start set manually the PreValue in the new system