# Migration from water-meter „old“ to water-meter “AI-on-the-edge-device”
|
|
|
|
!!! Warning
|
|
This page no longer is maintained!
|
|
|
|
There are only some few steps necessary to migrate your old system to the new one.
|
|
|
|
Please follow the following steps:
|
|
|
|
#### 1. Follow the installation guide to flash the ESP32CAM and prepare a SD Card with the content of the master
|
|
|
|
#### 2. Save the following files from the old Docker system on your PC:
|
|
|
|
* Reference Points 1-3 (only 2 needed)
|
|
* `Config.ini`
|
|
|
|
#### 3. Copy Reference Points 1-3 onto the new water-meter system (Directory `/config`)
|
|
|
|
**Please note only two Reference Points are supported in the new system.**
|
|
|
|
#### 4. Open new `config.ini` File:
|
|
|
|
Insert from the old `Config.ini` file `[alignment]` and `[alignment.ref0]` and `[alignment.ref1]` section the two Ref x and y position and the `initial_rotation_angle= 123`into the new `Config.ini` File, e.g.:
|
|
|
|
###### Old:
|
|
```
|
|
[alignment.ref0]
|
|
image=./config/RB01_65x65.jpg
|
|
pos_x=28
|
|
pos_y=63
|
|
|
|
[alignment.ref1]
|
|
image=./config/RB02_50x35.jpg
|
|
pos_x=497
|
|
pos_y=127
|
|
|
|
[alignment]
|
|
initial_rotation_angle=180
|
|
```
|
|
|
|
###### New:
|
|
|
|
```
|
|
[Alignment]
|
|
InitalRotate=180
|
|
/config/RB01_65x65.jpg 28, 63
|
|
/config/RB02_50x35.jpg 497, 127
|
|
SearchFieldX = 20
|
|
SearchFieldY = 20
|
|
```
|
|
|
|
|
|
#### 5. Insert the old Digit Values into the new `Config.ini` File, e.g.:
|
|
|
|
###### Old:
|
|
```
|
|
[Digital_Digit.ziffer1]
|
|
pos_x=265
|
|
pos_y=117
|
|
dx=28
|
|
dy=51
|
|
|
|
[Digital_Digit.ziffer2]
|
|
pos_x=310
|
|
pos_y=117
|
|
dx=28
|
|
dy=51
|
|
|
|
[Digital_Digit.ziffer3]
|
|
pos_x=354
|
|
pos_y=117
|
|
dx=28
|
|
dy=51
|
|
|
|
[Digital_Digit.ziffer4]
|
|
pos_x=399
|
|
pos_y=117
|
|
dx=28
|
|
dy=51
|
|
|
|
[Digital_Digit.ziffer5]
|
|
pos_x=445
|
|
pos_y=115
|
|
dx=28
|
|
dy=51
|
|
```
|
|
|
|
###### New:
|
|
```
|
|
[Digits]
|
|
Model=/config/dig0630s3.tflite
|
|
;LogImageLocation = /log/digit
|
|
ModelInputSize 20, 32
|
|
digit1, 265, 117, 28, 51
|
|
digit2, 310, 117, 28, 51
|
|
digit3, 354, 117, 28, 51
|
|
digit4, 399, 117, 28, 51
|
|
digit5, 445, 115, 28, 51
|
|
```
|
|
|
|
|
|
#### 6. Make sure that you have the same quality and size settings as in your old `Config.ini`
|
|
|
|
In the old configuration this was coded in the html-string for the image source:
|
|
###### Old:
|
|
```
|
|
URLImageSource=http://IP-ADRESS/capture_with_flashlight?quality=5&size=VGA
|
|
```
|
|
|
|
Default was Quality=5 and VGA.
|
|
|
|
###### New:
|
|
|
|
```
|
|
ImageQuality = 5
|
|
ImageSize = VGA
|
|
```
|
|
|
|
|
|
|
|
#### 7. Repeat the same for the analog section
|
|
|
|
#### 8. Insert your SSID and Password into the new wlan.ini File
|
|
|
|
#### 9. Compare and edit [ConsistencyCheck] Section with new [PostProcessing] Section
|
|
|
|
#### 10. Save new config.ini File in the new System.
|
|
|
|
#### 11. Restart the system.
|
|
|
|
#### 12. After the first start set manually the PreValue in the new system
|