Parameters
+This page lists all available Configuration Parameters.
+If a parameter or section has a tick box on its left side, you can disable it. +In such case the functionality gets disabled respectively the default values will be used.
+Note
+This is an auto-generated page! See the README for details!
+Note
+Due to a typo, one of the sections is called MakeImage instead of TakeImage!
+For backwards compatibility, this did not get changed.
List of all Parameters
+ + + + + + + + + + + + + +-
+
IO0
+IO1
+IO12
+IO13
+IO3
+IO4
+LEDColor
+LEDNumbers
+LEDType
+MainTopicMQTT
+
-
+
Database
+Measurement
+Uri
+password
+user
+
-
+
Brightness
+Contrast
+Demo
+FixedExposure
+ImageQuality
+ImageSize
+LEDIntensity
+LogImageLocation
+LogfileRetentionInDays
+Saturation
+WaitBeforeTakingPicture
+
-
+
CheckDigitIncreaseConsistency
+ErrorMessage
+NUMBER.AllowNegativeRates
+NUMBER.AnalogDigitalTransitionStart
+NUMBER.DecimalShift
+NUMBER.ExtendedResolution
+NUMBER.IgnoreLeadingNaN
+NUMBER.MaxRateType
+NUMBER.MaxRateValue
+PreValueAgeStartup
+PreValueUse
+
+
Section Alignment
+
+Parameter AlignmentAlgo
+Default Value: Default
Warning
+This is an Expert Parameter! Only change it if you understand what it does!
+Please fill me with an explanation and useful links.
++ + +
Parameter FlipImageSize
+Default Value: false
Warning
+This is an Expert Parameter! Only change it if you understand what it does!
+Note
+This parameter is not accessible through the Web Interface Configuration Page!
+Please fill me with an explanation and useful links.
++ + +
Parameter InitialMirror
+Default Value: false
Note
+This parameter is not accessible through the Web Interface Configuration Page!
+Please fill me with an explanation and useful links.
++ + +
Parameter InitialRotate
+Default Value: 179
Note
+This parameter is not accessible through the Web Interface Configuration Page!
+Please fill me with an explanation and useful links.
++ + +
Parameter SearchFieldX
+Default Value: 20
Warning
+This is an Expert Parameter! Only change it if you understand what it does!
+Please fill me with an explanation and useful links.
++ + +
Parameter SearchFieldY
+Default Value: 20
Warning
+This is an Expert Parameter! Only change it if you understand what it does!
+Please fill me with an explanation and useful links.
++ +
Section Analog
+
+Parameter CNNGoodThreshold
+Default Value: 0.5
Warning
+This is an Expert Parameter! Only change it if you understand what it does!
+Please fill me with an explanation and useful links.
++ + +
Parameter ExtendedResolution
+Default Value: true
Please fill me with an explanation and useful links.
++ + +
Parameter LogImageLocation
+Default Value: /log/analog
Please fill me with an explanation and useful links.
++ + +
Parameter LogfileRetentionInDays
+Default Value: 3
Please fill me with an explanation and useful links.
++ + +
Parameter Model
+Default Value: /config/ana-cont_11.3.1_s2.tflite
Please fill me with an explanation and useful links.
++ +
Section AutoTimer
+
+Parameter AutoStart
+Default Value: true
Warning
+This is an Expert Parameter! Only change it if you understand what it does!
+Please fill me with an explanation and useful links.
++ + +
Parameter Intervall
+Default Value: 5
Please fill me with an explanation and useful links.
++ +
Section DataLogging
+
+Parameter DataLogActive
+Default Value: true
Please fill me with an explanation and useful links.
++ + +
Parameter DataLogRetentionInDays
+Default Value: 3
Please fill me with an explanation and useful links.
++ +
Section Debug
+
+Parameter Logfile
+Default Value: 1
Please fill me with an explanation and useful links.
++ + +
Parameter LogfileRetentionInDays
+Default Value: 3
Please fill me with an explanation and useful links.
++ +
Section Digits
+
+Parameter CNNGoodThreshold
+Default Value: 0.5
Warning
+This is an Expert Parameter! Only change it if you understand what it does!
+Please fill me with an explanation and useful links.
++ + +
Parameter LogImageLocation
+Default Value: /log/digit
Please fill me with an explanation and useful links.
++ + +
Parameter LogfileRetentionInDays
+Default Value: 3
Please fill me with an explanation and useful links.
++ + +
Parameter Model
+Default Value: /config/dig-cont_0600_s3.tflite
Please fill me with an explanation and useful links.
++ +
Section GPIO
+
+Parameter IO0
+Default Value: input disabled 10 false false
Warning
+This is an Expert Parameter! Only change it if you understand what it does!
+Please fill me with an explanation and useful links.
++ + +
Parameter IO1
+Default Value: input disabled 10 false false
Warning
+This is an Expert Parameter! Only change it if you understand what it does!
+Please fill me with an explanation and useful links.
++ + +
Parameter IO12
+Default Value: input-pullup disabled 10 false false
Warning
+This is an Expert Parameter! Only change it if you understand what it does!
+Please fill me with an explanation and useful links.
++ + +
Parameter IO13
+Default Value: input-pullup disabled 10 false false
Warning
+This is an Expert Parameter! Only change it if you understand what it does!
+Please fill me with an explanation and useful links.
++ + +
Parameter IO3
+Default Value: input disabled 10 false false
Warning
+This is an Expert Parameter! Only change it if you understand what it does!
+Please fill me with an explanation and useful links.
++ + +
Parameter IO4
+Default Value: built-in-led disabled 10 false false
Warning
+This is an Expert Parameter! Only change it if you understand what it does!
+Please fill me with an explanation and useful links.
++ + +
Parameter LEDColor
+Default Value: 150 150 150
Please fill me with an explanation and useful links.
++ + +
Parameter LEDNumbers
+Default Value: 2
Please fill me with an explanation and useful links.
++ + +
Parameter LEDType
+Default Value: WS2812
Please fill me with an explanation and useful links.
++ + +
Parameter MainTopicMQTT
+Default Value: wasserzaehler/GPIO
Note
+This parameter is not accessible through the Web Interface Configuration Page!
+Please fill me with an explanation and useful links.
++ +
Section InfluxDB
+
+Parameter Database
+Default Value: ``
+Please fill me with an explanation and useful links.
++ + +
Parameter Measurement
+Default Value: undefined
Please fill me with an explanation and useful links.
++ + +
Parameter Uri
+Default Value: undefined
Please fill me with an explanation and useful links.
++ + +
Parameter password
+Default Value: undefined
Please fill me with an explanation and useful links.
++ + +
Parameter user
+Default Value: undefined
Please fill me with an explanation and useful links.
++ +
Section MQTT
+
+Parameter ClientID
+Default Value: watermeter
Please fill me with an explanation and useful links.
++ + +
Parameter HomeassistantDiscovery
+Default Value: true
Please fill me with an explanation and useful links.
++ + +
Parameter MainTopic
+Default Value: watermeter
Please fill me with an explanation and useful links.
++ + +
Parameter MeterType
+Default Value: other
Please fill me with an explanation and useful links.
++ + +
Parameter SetRetainFlag
+Default Value: true
Please fill me with an explanation and useful links.
++ + +
Parameter Uri
+Default Value: mqtt://IP-ADRESS:1883
Please fill me with an explanation and useful links.
++ + +
Parameter password
+Default Value: PASSWORD
Please fill me with an explanation and useful links.
++ + +
Parameter user
+Default Value: USERNAME
Please fill me with an explanation and useful links.
++ +
Section MakeImage
+
+Parameter Brightness
+Default Value: 0
Warning
+This is an Expert Parameter! Only change it if you understand what it does!
+Please fill me with an explanation and useful links.
++ + +
Parameter Contrast
+Default Value: 0
Warning
+This is an Expert Parameter! Only change it if you understand what it does!
+Please fill me with an explanation and useful links.
++ + +
Parameter Demo
+Default Value: false
Please fill me with an explanation and useful links.
++ + +
Parameter FixedExposure
+Default Value: false
Warning
+This is an Expert Parameter! Only change it if you understand what it does!
+Please fill me with an explanation and useful links.
++ + +
Parameter ImageQuality
+Default Value: 12
Warning
+This is an Expert Parameter! Only change it if you understand what it does!
+Please fill me with an explanation and useful links.
++ + +
Parameter ImageSize
+Default Value: VGA
Warning
+This is an Expert Parameter! Only change it if you understand what it does!
+Please fill me with an explanation and useful links.
++ + +
Parameter LEDIntensity
+Default Value: 50
Warning
+This is an Expert Parameter! Only change it if you understand what it does!
+Please fill me with an explanation and useful links.
++ + +
Parameter LogImageLocation
+Default Value: /log/source
Please fill me with an explanation and useful links.
++ + +
Parameter LogfileRetentionInDays
+Default Value: 15
Please fill me with an explanation and useful links.
++ + +
Parameter Saturation
+Default Value: 0
Warning
+This is an Expert Parameter! Only change it if you understand what it does!
+Please fill me with an explanation and useful links.
++ + +
Parameter WaitBeforeTakingPicture
+Default Value: 5
Warning
+This is an Expert Parameter! Only change it if you understand what it does!
+Please fill me with an explanation and useful links.
++ +
Section PostProcessing
+
+Parameter CheckDigitIncreaseConsistency
+Default Value: false
Warning
+This is an Expert Parameter! Only change it if you understand what it does!
+Please fill me with an explanation and useful links.
++ + +
Parameter ErrorMessage
+Default Value: true
Warning
+This is an Expert Parameter! Only change it if you understand what it does!
+Please fill me with an explanation and useful links.
++ + +
Parameter NUMBER.AllowNegativeRates
+Default Value: false
Please fill me with an explanation and useful links.
++ + +
Parameter NUMBER.AnalogDigitalTransitionStart
+Default Value: 9.2
Please fill me with an explanation and useful links.
++ + +
Parameter NUMBER.DecimalShift
+Default Value: 0
Please fill me with an explanation and useful links.
++ + +
Parameter NUMBER.ExtendedResolution
+Default Value: false
Please fill me with an explanation and useful links.
++ + +
Parameter NUMBER.IgnoreLeadingNaN
+Default Value: true
Please fill me with an explanation and useful links.
++ + +
Parameter NUMBER.MaxRateType
+Default Value: AbsoluteChange
Please fill me with an explanation and useful links.
++ + +
Parameter NUMBER.MaxRateValue
+Default Value: 0.05
Please fill me with an explanation and useful links.
++ + +
Parameter PreValueAgeStartup
+Default Value: 720
Warning
+This is an Expert Parameter! Only change it if you understand what it does!
+Please fill me with an explanation and useful links.
++ + +
Parameter PreValueUse
+Default Value: true
Please fill me with an explanation and useful links.
++ +
Section System
+
+Parameter AutoAdjustSummertime
+Default Value: false
Note
+This parameter is not accessible through the Web Interface Configuration Page!
+Please fill me with an explanation and useful links.
++ + +
Parameter Hostname
+Default Value: undefined
Warning
+This is an Expert Parameter! Only change it if you understand what it does!
+Please fill me with an explanation and useful links.
++ + +
Parameter RSSIThreashold
+Default Value: 0
Warning
+This is an Expert Parameter! Only change it if you understand what it does!
+Please fill me with an explanation and useful links.
++ + +
Parameter SetupMode
+Default Value: true
Note
+This parameter is not accessible through the Web Interface Configuration Page!
+Please fill me with an explanation and useful links.
++ + +
Parameter TimeServer
+Default Value: pool.ntp.org
Warning
+This is an Expert Parameter! Only change it if you understand what it does!
+Please fill me with an explanation and useful links.
++ + +
Parameter TimeZone
+Default Value: CET-1CEST,M3.5.0,M10.5.0/3
Please fill me with an explanation and useful links.
++ +