mirror of
https://github.com/jomjol/AI-on-the-edge-device-docs.git
synced 2025-12-09 13:06:56 +03:00
Deployed 7c38213 with MkDocs version: 1.4.2
This commit is contained in:
@@ -110,7 +110,7 @@
|
||||
</li>
|
||||
<li class="toctree-l1"><a class="reference internal" href="../Configuration/">Configuration</a>
|
||||
</li>
|
||||
<li class="toctree-l1"><a class="reference internal" href="../Watermeter-specific-analog---digital-transition/">Analog/Digital Transition on Watermeters</a>
|
||||
<li class="toctree-l1"><a class="reference internal" href="../Watermeter-specific-analog---digital-transition/">Analog/Digital Transition on Water Meters</a>
|
||||
</li>
|
||||
<li class="toctree-l1"><a class="reference internal" href="../collect-new-images/">Collect images to improve the models</a>
|
||||
</li>
|
||||
@@ -158,12 +158,12 @@
|
||||
<ul>
|
||||
<li class="toctree-l1"><a class="reference internal" href="../outdated--Integrated-Functions/">Integrated Functions</a>
|
||||
</li>
|
||||
<li class="toctree-l1"><a class="reference internal" href="../outdated--Gasmeter-Log-Downloader/">Gasmeter Log-Downloader</a>
|
||||
<li class="toctree-l1"><a class="reference internal" href="../outdated--Gasmeter-Log-Downloader/">Gas Meter Log Downloader</a>
|
||||
</li>
|
||||
<li class="toctree-l1"><a class="reference internal" href="../outdated--Migrate-Old-Config-To-New-Config/">Migration from water-meter „old“ to water-meter “AI-on-the-edge-device”</a>
|
||||
</li>
|
||||
</ul>
|
||||
<p class="caption"><span class="caption-text">Asorted Pages</span></p>
|
||||
<p class="caption"><span class="caption-text">Assorted Pages</span></p>
|
||||
<ul>
|
||||
<li class="toctree-l1"><a class="reference internal" href="../Graphical-Configuration/">Graphical Configuration</a>
|
||||
</li>
|
||||
@@ -217,7 +217,7 @@
|
||||
<p>Ensure a sharp image of the camera by adjusting the focal length of the ESP OV2640 camera. <strong>Adjust the focus for the clearest possible image!</strong></p>
|
||||
<p>In order to use it for reading a meter, the focal-length of the OV2640 camera has to be manipulated, as by default it only results in sharp image for distance bigger than ~40cm, causing the image of the water meter to be too small for automated readout processing.</p>
|
||||
<p><strong>ATTENTION:</strong> this modification will void any warranty, as the sealing of the lens objective is broken!</p>
|
||||
<p><strong>ATTENTION:</strong> This modification will render the camera unsuitable for general, web-cam type applications unless the focal length is changed back to the original setting.</p>
|
||||
<p><strong>ATTENTION:</strong> This modification will render the camera unsuitable for general, web-cam type applications unless the focal length is changed back to the original setting.</p>
|
||||
<p><img alt="" src="../img/focus_adjustment.jpg" /></p>
|
||||
<p>Remove the fixing glue of the OV2640 lens with a sharp knife. After this you can screw the lens in and out. Rotating it by about a quarter of a turn counterclockwise results in a focus plane of about 10cm. You need to figure out your best setting with a little bit of trial and error for your specific environment.</p>
|
||||
<h3 id="horizontal-alignment">Horizontal Alignment</h3>
|
||||
|
||||
Reference in New Issue
Block a user