@@ -247,7 +247,7 @@
<p>1) <strong>AbsolutChange</strong>: Here the difference between the PreValue and the current reading is compared directly, independent how much time has passed since the last reading.
2) <strong>RelativeRate</strong>: in this case a change rate in the unit of change/minute is calculated, taking the time between the last and the current reading into account. Be careful, that with increasing time, the absolute allowed change increases.
Example: relative rate of 0.05 m³/minute --&gt; after 20 minutes a maximum change of 20 minutes * 0.05 m³/minute = 1 m³ is possible. That means that a false reading of 1 m³ cannot be detected false after about 20 minutes in this case
Assume, that there might me no change in the meter for hours (e.g. during the night) a much bigger change could also be accepted. </p>
Assume, that there might be no change in the meter for hours (e.g. during the night) a much bigger change could also be accepted. </p>
<h6 id="extendedresolution"><code>ExtendedResolution</code></h6>
<p>Newer models such as dig-cont and dig-class100 have a high resolution of the values and can thus represent another digit by using the value of the last digit or pointer (ex. 7.8 in the last digit). </p>
<p>If the value is set to true, the result of the last digit is used completely. </p>